PQ 500-1

PQ 300-1

  • Rope Type:  12.5 mm static kernmantle rope
  • Weight:  28 pounds/12.8 kg
  • Dimensions:  18”x 10”x 12.5”
  • Lifting Capacity: 

500 lbs (227 kg) net

550 lbs (249 kg) gross

  • Lift Speed:  0.6 ft/sec (0.18 m/sec)
  • Operating Temperature:  32°F to 113°F (0°C to 45°C)
  • Load Test:

Dynamic:  0.6 m drop with full rated load equals approximately 2,600 lb (1,179 kg) force

Maximum load without slipping is 1,100 lbs (499 kg)

  • Forward and reverse power control
  • Rechargeable 36 volt battery pack  (15.5” x 7”, 14 lbs)
  • Continuous lift distance: 200 ft, then rest 5 min.
  • Climbing time per battery charge averages 12 minutes (600 ft/183 m)

 

  • Uses standard rope/climbing gear and accessories
  • Power descent or manual brake release
  • Can use in wet environments, use protective cover for rain (do not immerse in liquid)
  • Can use in oily, dirty , dusty operations
  • HAZARDOUS ENVIRONMENTS  Designed and tested for use in Level 1, Division II hazardous atmospheres
  • Rope Type:  11 mm static kernmantle rope
  • Weight:  18 pounds/8.2 kg
  • Dimensions:  18”x 10”x 10.5”
  • Lifting Capacity:

300 lbs (136 kg) net

350 lbs (158 kg) gross

  • Lift Speed:  1 ft/sec (0.3 m/sec)
  • Operating Temperature:  32°F to 113°F (0°C to 45°C)
  • Load Test:

Dynamic:  0.6 m drop with full rated load equals approximately 1,500 lb (680 kg) force

Maximum load without slipping is 700 lbs

  • Forward and reverse power control
  • Rechargeable 36 volt battery pack  (15.5” x 7”, 14 lbs)
  • Continuous lift distance: 200 ft, then rest 5 min.
  • Climbing time per battery charge averages 12 minutes (800 ft/244 m)

 

  • Uses standard rope/climbing gear and accessories
  • Power descent or manual brake release
  • Can use in wet environments, use protective cover for rain (do not immerse in liquid)
  • Can use in oily, dirty , dusty operations
  • HAZARDOUS ENVIRONMENTS  Designed and tested for use in Level 1, Division II hazardous atmospheres